Product introduction
Postpartum rehabilitation therapeutic instrument is a product mainly for gynecology and obstetrics, which is developed based on the theory and clinical practice of low-frequency electrotherapy of low-frequency pulse current in the treatment of diseases. Multiple groups of treatment modes are set in an optimized way, which are automatically controlled by the computer chip. The low-frequency pulse stimulation is carried out on specific parts of the human body through the special treatment electrode, which has a physical effect on the local part of the human body and regulates the internal environment of the human body, so as to dredge the breast duct, promote milk secretion, accelerate uterine recovery, promote postpartum micturition, relieve postpartum pain Accelerate wound healing and other clinical therapeutic effects.
Instrument features:
Prolactin: the postpartum rehabilitation therapeutic instrument can excite the breast neuromuscular tissue, make the muscle produce rhythmic contraction and operation, produce extrusion effect and rotation effect from the periphery to the nipple, promote the smooth flow of breast duct, improve local circulation, stimulate the secretion of pituitary prolactin, and achieve the purpose of promoting milk secretion and breastfeeding.
Postpartum rehabilitation therapeutic instrument can accelerate uterine recovery: it can effectively restore the tension and elasticity of muscle fascia, accelerate uterine involution, reduce bleeding, promote intraluminal circulation, reduce the occurrence of burst disease and shorten the natural recovery time.
Postpartum rehabilitation therapeutic instrument for the treatment of chronic pelvic inflammation: it can promote the local pelvic circulation of patients, improve tissue nutrition, improve metabolism, facilitate the absorption and regression of inflammation in the cavity, and have a good inhibitory effect on pelvic pain
technical parameter
Power supply: AC220±10% 50Hz±1Hz
Input power consumption:≤100W
Basic pulse waveform and frequency: 800Hz±8%
Modulation pulse waveform and frequency: trapezoidal wave 0.5-10hz; Triangular wave 1-20hz; Bell wave 0.5-10hz.
Open circuit voltage:≤500Vp-p
Significant value of large output amplitude:≤40V
Working time: the operation mode of the instrument is discontinuous, and the working time is≥6h。
The contraindications of postpartum rehabilitation therapeutic instrument include cardiac pacemaker, patients with severe heart disease and hyperthyroidism;